{"product_id":"fireguard-fgt-7-aviation-4hr-with-pump-bay-10ft-hc-double-wall-tank-unity-fuel-solutions","title":"Fireguard FGT 7 Aviation 4HR With Pump Bay (10FT\/HC) Double Wall Tank - Unity Fuel Solutions","description":"\u003cp class=\"MsoNormal\"\u003eThe Fireguard FGT 7 Aviation 4HR With Pump Bay (10FT\/HC) Double Wall Tank by Unity Fuel Solutions is a high-performance, aboveground aviation fuel storage and dispensing system built for mission-critical safety, contaminant-free operation, and regulatory compliance. Engineered for compactness and operational reliability, this model delivers best-in-class four-hour fire protection, aviation-grade construction, and a dedicated pump bay—ideal for airports, FBOs, and aviation fueling sites with space or volume constraints.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003e7,000-gallon (approx. 26,500 liters) capacity in a compact 10-foot high-cube (HC) rectangular footprint for efficient aviation fuel storage at smaller or space-constrained sites.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDouble-wall mild steel outer tank with proprietary lightweight 3-inch fireproof insulation provides certified 4-hour fire rating (UL-2085 Protected Aboveground Tank), ensuring top-tier fire safety.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAviation-grade stainless steel inner tank and wetted piping preserve avgas, jet fuel, or dedicated aviation blends—guaranteeing fuel purity, corrosion resistance, and compliance for critical aviation operations.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eIntegrated, secure pump bay supports protected, on-site aircraft or ground support fueling while shielding sensitive dispensing equipment from weather or tampering.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eUL-2085 “Insulated Secondary Containment” and UL-142 certified for leading fire, ballistic, and impact resistance—meeting or exceeding all stringent international and U.S. requirements for aviation fueling infrastructure.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eIntegral secondary containment (minimum 110% tank volume) eliminates the need for external bunds\/diking, streamlining site approval and reducing installation complexity.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLeak-detectable interstitial space allows for rapid, ongoing environmental monitoring and compliance testing.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eLightweight insulation dramatically reduces shipping, handling, and installation costs, enabling faster site commissioning.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSuitable for both indoor and outdoor installation—4-hour fire rating allows for reduced code-mandated separation distances per NFPA, FAA, and local regulations.\u003c\/li\u003e\n\u003cli style=\"mso-list: l1 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eReady for a wide range of aviation accessories: fuel management systems, fill\/vent\/overfill protection, ladders, platforms, and advanced monitoring as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eCompliance and Safety:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eExceeds all UL-2085 and UL-142 requirements for fire, impact, and projectile resistance.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eBuilt to Steel Tank Institute F-941 and fully compliant with CARB (California Air Resource Board) emissions standards.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eMeets or exceeds NFPA 30\/30A, ULC S655 (Canada), FAA guidelines, and all principal federal, state, and international AST\/aviation code requirements.\u003c\/li\u003e\n\u003cli style=\"mso-list: l2 level1 lfo2; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFactory-fitted with emergency venting, overfill protection, robust corrosion control, and real-time environmental monitoring for total regulatory confidence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eSuitable For:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAirports, FBOs, heliports, and remote airfields that require contaminant-free, compact aviation fuel storage with integrated, weather-protected aircraft fueling capability.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAviation maintenance, refueling operations, or ground support requiring best-in-class fire safety and operational flexibility in limited space.\u003c\/li\u003e\n\u003cli style=\"mso-list: l3 level1 lfo3; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eAny aviation, commercial, or government fueling site demanding regulatory compliance, assured fuel purity, and minimized site impact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCapacity: 7,000 gallons (approx. 26,500 liters)\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDimensions: 10FT\/HC rectangular (approx. 3,048mm length × 2,438mm width × 2,896mm height—please confirm with supplier)\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eConstruction: Double-wall mild steel with proprietary 3-inch fireproof insulation; aviation-grade stainless steel inner tank and all wetted piping\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFire Protection: Certified 4-hour fire rating (UL-2085 Protected Tank)\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003ePump Bay: Integrated, weather-sealed, supports aviation-grade dispensing\/monitoring systems\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eSecondary Containment: Integral—minimum 110% of tank capacity, continuous interstitial monitoring\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eCertifications: UL-2085, UL-142, STI Fireguard, ULC S655 (Canada), CARB, FAA guidance, and all applicable aviation fuel storage standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eChoose the Fireguard FGT 7 Aviation 4HR With Pump Bay (10FT\/HC) Double Wall Tank to ensure flexible, contaminant-free, code-compliant aviation fuel storage in space-conscious, mission-critical aviation environments. Its robust UL-listed construction, best-in-class fire rating, and integrated dispensing make it the trusted solution for safe, reliable aviation fueling anywhere reliability and safety are paramount.\u003c\/p\u003e","brand":"Unity Fuel Solutions","offers":[{"title":"Default Title","offer_id":48777430729012,"sku":"FGT7\/4AV","price":99999.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/Unity-Fuel-Solutions-Logo.jpg?v=1754508204","url":"https:\/\/innoflo.com\/fr\/products\/fireguard-fgt-7-aviation-4hr-with-pump-bay-10ft-hc-double-wall-tank-unity-fuel-solutions","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}