{"product_id":"graco-96g105-g3-a-max-grease-lubrication-pump-24-vdc-12l-low-level-with-controller-3-sensors-din-machine-count-vent-valve-alarm-remote-manual-run-4","title":"GRACO G3 Max Grease Lubrication Pump, 24 VDC, 12L, Low Level with Controller, 3 Sensors, DIN, Machine Count, Vent Valve, Alarm, Remote Manual Run - (SKU: 96G105)","description":"\u003cp class=\"MsoNormal\"\u003eThe GRACO 96G105 G3 Max Grease Lubrication Pump is an automatic lubrication system designed for reliable, programmable dispensing of grease (up to NLGI #2) or oil in industrial applications. It features a robust construction suitable for demanding environments and is intended to ensure consistent lubrication for machinery, reducing downtime and maintenance needs.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAutomatic grease\/oil lubrication pump\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eG3 Max, 12L reservoir\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eIndustrial-grade materials, designed for durability\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAdjustable pump output per element per minute: 0.12 in³, 0.18 in³, 0.25 in³ (2 cm³, 3 cm³, 4 cm³)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMax pressure: 5100 psi (352 bar)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with NLGI #000 to #2 greases and oil with at least 40cSt\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCE, ETL, IP69K; Conforms to UL 73, certified to CSA 22.2 No. 68-09\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBuilt-in controller with selectable pump on\/off timer\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLow level indicator with warning and shutdown alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMonitoring of up to three independent zones\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eProgrammable machine count feature\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAlarm signal for lube system shutdown\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eWarning signal prior to shutdown\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePassword protected access to controls\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePre-lube capability\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEasy-to-use navigation keys\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRemote manual run\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eVent valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eSuitable for industrial, mining, construction, agriculture, and transportation sectors where consistent, automated lubrication is required for machinery and equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Notes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUsing genuine GRACO parts ensures compatibility, reliability, and optimal performance of the lubrication system.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMount the pump securely using the DIN rail mounting system\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure proper electrical connections for 24 VDC power supply\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eConnect sensors and alarms as per the manual\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eProgram the controller for desired lubrication intervals and machine count\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly check and maintain the reservoir and vent valve\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFollow all safety instructions and local regulations\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly inspect for leaks and proper sensor function\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eKeep the reservoir filled to avoid low level alarms and shutdowns\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse only compatible greases and oils as specified\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eConsult the manual for troubleshooting and maintenance schedules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GRACO Air Valves \u0026 Regulators","offers":[{"title":"Default Title","offer_id":48487449362740,"sku":"96G105","price":99999.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/Graco_Innoflo_d3ff2a6c-111a-45fc-b7f2-1ecf581f026e.webp?v=1740934632","url":"https:\/\/innoflo.com\/fr\/products\/graco-96g105-g3-a-max-grease-lubrication-pump-24-vdc-12l-low-level-with-controller-3-sensors-din-machine-count-vent-valve-alarm-remote-manual-run-4","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}