{"product_id":"graco-564402-field-sensitive-magnetic-proximity-cycle-115-vac-5-pin-bh-mini-mgo-divider-valves","title":"GRACO Field Sensitive Magnetic Proximity Cycle Switch, 115 VAC, 5-Pin BH Mini – MGO Divider Valves - (SKU: 564402)","description":"\u003cp class=\"MsoNormal\"\u003eThe GRACO 564402 is a proximity switch designed for use with MGO divider valves in automatic lubrication systems. It is constructed with robust materials for industrial environments and is intended to provide cycle feedback to monitors, controllers, or PLCs, enabling accurate monitoring and recording of lubrication cycles.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eField Sensitive Magnetic (FSM) Proximity Switch\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003e564402 (527-007-160), 5-Pin BH Mini\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAluminum housing, stainless steel magnet housing, Buna-N O-ring\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUp to 10,000 psi (690 bar) for some models; for FSM switches, up to 8,000 psi (552 bar) is typical for MX, MXP, and MGO valve sections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMGO Divider Valves\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMagnetically actuated, dry contact switch\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eProvides cycle rate and cycle count feedback\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for reliable operation in harsh environments\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEasy to install and maintain\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSuitable for both oil and grease applications (depending on specific model and configuration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUsed in automatic lubrication systems to monitor and record the number of cycles and cycle rate of Series-Progressive (SP) divider valves, ensuring proper lubrication and system health.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Notes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUsing genuine GRACO parts ensures compatibility, reliability, and optimal performance of the lubrication system.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure power is disconnected before installation or maintenance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eInstall according to local electrical codes and regulations\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse only qualified electricians for wiring\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGround the equipment properly to prevent electric shock\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRefer to the equipment manual for specific installation instructions\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly inspect for wear or damage\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure O-rings and seals are intact\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eKeep connections clean and secure\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFollow manufacturer’s recommended maintenance schedule\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GRACO Air Valves \u0026 Regulators","offers":[{"title":"Default Title","offer_id":48485918114100,"sku":"564402","price":1675.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/Graco_Innoflo_04e430f6-303d-420e-a542-9d76a9eb52ef.webp?v=1740817313","url":"https:\/\/innoflo.com\/products\/graco-564402-field-sensitive-magnetic-proximity-cycle-115-vac-5-pin-bh-mini-mgo-divider-valves","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}