{"product_id":"graco-96g216-g3-a-max-grease-lubrication-pump-24-vdc-8-liter-low-level-with-controller-normally-open-vent-valve-with-alarm-manual-run-cpc-1-sensor-3","title":"GRACO G3 Max Grease Lubrication Pump, 24 VDC, 8 Liter, Low Level with Controller, Normally Open Vent Valve with Alarm, Manual Run, CPC, 1 Sensor - (SKU: 96G216)","description":"\u003cp class=\"MsoNormal\"\u003eThe GRACO 96G216 G3 Max is an electric piston pump designed for automatic lubrication systems. It is constructed for use with grease (NLGI #000–#2) and is intended to provide reliable, automated lubrication for on-road vehicles, off-road equipment, and industrial machinery. The pump features a controller, low-level monitoring, a normally open vent valve with alarm, manual run capability, and CPC connectivity with one sensor.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eElectric piston pump\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eG3 Max, 8 Liter reservoir\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUp to 5100 psi (35.1 MPa, 351.6 bar) pump output pressure (for G3 Max series)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with NLGI #000–#2 greases and oils with at least 40cSt; works with injector-based and series progressive systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eConforms to ANSI\/UL 73; Certified to CAN\/CSA C22.2 No 68 (for G3 Max series)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAdjustable pump element (standard, plus room for two more)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLow-level monitoring with alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eNormally open vent valve with alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eManual run capability\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCPC connectivity with one sensor\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFlexible design for multiple applications\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eReliable, automated lubrication\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEasy to maintain\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eOn-road vehicles, off-road equipment, industrial machinery requiring automated lubrication\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Notes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUsing genuine GRACO parts ensures optimal performance, reliability, and compatibility with GRACO equipment.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eConnect to a fused power source (24 VDC)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure proper grounding and electrical safety\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse only compatible greases (NLGI #000–#2) and oils (minimum 40cSt)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDo not operate without reservoir attached\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eClean inlet fitting before filling reservoir to prevent contamination\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDo not overfill reservoir\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eTighten pump element fitting to 50 in. lbs (5.6 N•m)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFollow all safety instructions in the manual\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFor injector or series progressive systems, ensure correct valve and sensor installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GRACO Air Valves \u0026 Regulators","offers":[{"title":"Default Title","offer_id":48487450280244,"sku":"96G216","price":99999.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/Graco_Innoflo_ef5a579a-8bbb-4a54-9c76-fb6d15ae025b.webp?v=1740934723","url":"https:\/\/innoflo.com\/products\/graco-96g216-g3-a-max-grease-lubrication-pump-24-vdc-8-liter-low-level-with-controller-normally-open-vent-valve-with-alarm-manual-run-cpc-1-sensor-3","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}