{"product_id":"graco-96g550-pump-g3-g-acm2-4l0l00-rmcd0a0vp","title":"GRACO G3 Max Full-Featured Grease Lubrication Pump, 4L Reservoir - (SKU: 96G550)","description":"\u003cp class=\"MsoNormal\"\u003eThe GRACO 96G550 (G3-G-ACM2-4L0L00-RMCD0A0VP) is a full-featured grease lubrication pump designed for reliable, automated lubrication of machinery. It features a 4-liter grease reservoir with a follower plate and low-level paddle, constructed from robust materials suitable for industrial environments. This pump is intended for use in injector-based or series progressive lubrication systems to extend machinery life, reduce operating costs, and increase productivity.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGrease Lubrication Pump\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eG3 Max, 4L Reservoir\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eWorks with injector-based or series progressive lubrication systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLCD screen for detailed pump status and operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAlarm screens with troubleshooting tips and QR code for training\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBright LEDs with nearly 180-degree viewing angle\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLow level indicator with alert and shut-down alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eManual run and remote run options\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePassword protection for settings\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePre-lube function for cycle initiation on start-up\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCycle switch or pressure sensor compatibility (PNP, NPN, dry contact, analog\/digital sensors)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMachine count input for inconsistently used equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDIN alarm relay connection for remote status indication\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with normally open vent valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eAutomated lubrication of industrial machinery in various sectors, including mining, agriculture, and manufacturing, to ensure optimal equipment performance and longevity.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Notes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUsing genuine GRACO parts ensures compatibility, reliability, and optimal performance of the lubrication system.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure proper electrical connections using DIN Form-A connectors for power input and alarm relay output\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse M12 connectors for vent valve and sensor connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFollow manufacturer guidelines for reservoir filling and system priming\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly check and maintain the low-level indicator and alarm functions\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eConsult the equipment manual for detailed installation and maintenance procedures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GRACO General Components","offers":[{"title":"Default Title","offer_id":48486862029108,"sku":"96G550","price":3650.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/96G549_23c85bbd-5da5-411f-8569-cbee5623a66e.jpg?v=1740894626","url":"https:\/\/innoflo.com\/products\/graco-96g550-pump-g3-g-acm2-4l0l00-rmcd0a0vp","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}