{"product_id":"graco-96g570-pump-g3-g-acm2-4lfl00-rmcd0a0vp","title":"GRACO G3® Max Full-Featured Grease Lubrication Pump, 90-240 VAC, 4 Liter Reservoir - (SKU: 96G570)","description":"\u003cp class=\"MsoNormal\"\u003eThe GRACO 96G570 is a full-featured electric grease lubrication pump designed for use in industrial and vehicle service applications. It features a 4-liter reservoir with a follower plate and low level paddle, and is constructed for durability and reliability. Its primary function is to deliver precise lubrication to machinery, extending equipment life, reducing operating costs, and increasing productivity. The pump is compatible with both injector-based and series progressive lubrication systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eElectric grease lubrication pump\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eG3® Max, 4 liter reservoir\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDurable industrial construction with follower plate and low level paddle\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eWorks with injector-based or series progressive systems\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLCD screen for detailed pump status and operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAlarm screens with troubleshooting tips and QR code for training\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBright LEDs with nearly 180° viewing angle\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLow level indicator with alert and shut-down alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eManual run (remote option available)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePassword protection for settings\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePre-lube function for start-up cycles\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMachine count input for inconsistently used equipment\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDIN alarm relay connection for stack light integration\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCompatible with normally open vent valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eIdeal for industrial machinery, vehicle service, and any application requiring reliable, automated lubrication. Suitable for both consistently and inconsistently used equipment.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Notes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUsing genuine GRACO parts ensures compatibility, reliability, and optimal performance of the lubrication system.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure proper electrical connections using DIN Form-A connectors for power input and alarm relay output\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse M12 connectors for vent valve and cycle\/pressure sensor connections\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFollow manufacturer guidelines for reservoir filling and system priming\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly check and maintain the low level indicator and alarm system\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eConsult the manual for specific wiring and programming instructions\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eMonitor pump status via LCD and alarm screens\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly inspect and clean the reservoir and follower plate\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eTest alarm and low level indicator functionality periodically\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUpdate firmware and settings as recommended by GRACO\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GRACO General Components","offers":[{"title":"Default Title","offer_id":48486862422324,"sku":"96G570","price":4250.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/96G549_1bae1d70-776b-4ecd-a596-99994c9e6ef9.jpg?v=1740894656","url":"https:\/\/innoflo.com\/products\/graco-96g570-pump-g3-g-acm2-4lfl00-rmcd0a0vp","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}