{"product_id":"graco-te80-1402-quantm-i80-1-5flange-pvdf-kynar-electric-diaphragm-pump-380-480-vac-3ph-fep-al-center-pv-seat-pt-ball-po-diaphragm","title":"GRACO QUANTM i80, 1.5\" Flange, PVDF (Kynar) Electric Diaphragm Pump - (SKU: TE80-1402)","description":"\u003cp class=\"MsoNormal\"\u003eThe GRACO TE80-1402 QUANTM i80 is a 1.5-inch flanged electric operated double diaphragm (EODD) pump with a PVDF (Kynar) fluid section, designed for highly corrosive environments. It is intended for efficient, reliable fluid transfer of aggressive chemicals and is suitable for integration into industrial production lines.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eElectric Operated Double Diaphragm (EODD) Pump\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eQUANTM i80, 1.5\" (38.1 mm) Flange\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePVDF (Kynar) fluid section, FEP aluminum center, PV seat, PT ball, PO diaphragm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUp to 80 gallons per minute (300 LPM) for standard i80 models; confirm for TE80-1402\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDesigned for use with aggressive chemicals and detergents; compatible with 380–480 VAC, 3-phase power\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eLightweight, compact design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eReduces energy use and manufacturing costs\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePlug-and-play installation for easy replacement\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eHigh corrosion resistance due to PVDF (Kynar) construction\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eReliable, low-maintenance operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUp to 8x more continuous torque at low speeds than conventional motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eIdeal for fluid transfer of aggressive chemicals, detergents, and high\/low pH materials in industrial, mining, and agricultural settings. Suitable for sump evacuation and production line integration.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInstallation Notes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUsing genuine GRACO parts ensures optimal performance, reliability, and compatibility with existing equipment.\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEnsure power supply matches pump requirements (380–480 VAC, 3-phase)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eVerify flange connections for proper sealing\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFollow manufacturer guidelines for diaphragm and ball\/seat maintenance\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eInspect for leaks and proper alignment before operation\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRegularly inspect diaphragms, balls, and seats for wear\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eClean fluid section as needed to prevent buildup\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eUse only genuine replacement parts for repairs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GRACO Diaphragms \u0026 Seals","offers":[{"title":"Default Title","offer_id":48486961676596,"sku":"TE80-1402","price":14450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0024\/4508\/2699\/files\/QUANTM_i80_PP_FF_cc24bad6-bfd5-4ae6-9a0d-3b23326e8d18.jpg?v=1740902989","url":"https:\/\/innoflo.com\/products\/graco-te80-1402-quantm-i80-1-5flange-pvdf-kynar-electric-diaphragm-pump-380-480-vac-3ph-fep-al-center-pv-seat-pt-ball-po-diaphragm","provider":"Innoflo Solutions Inc.","version":"1.0","type":"link"}