The GRACO 96G018 G3 Max Grease Lubrication Pump is a robust, automatic lubrication system component designed for reliable grease dispensing in industrial environments. It features a 2-liter reservoir with a follower plate, low-level monitoring, a controller, one sensor, CPC (Centralized Pressure Control) capability, vent valve, and remote manual run functionality. The pump is constructed for durability and is intended for use with NLGI #000 to #2 greases, suitable for a wide range of automatic lubrication applications.
Key Features:
Automatic grease lubrication pump
G3 Max, 24 VDC, 2L reservoir
Industrial-grade materials, designed for durability
Up to 5100 psi (35.1 MPa, 351.6 bar) pump output pressure; 5000 psi (34.4 MPa, 344.7 bar) maximum working pressure (for G3 Max series, actual may vary by configuration)
Compatible with NLGI #000 to #2 greases and oils with at least 40cSt viscosity
Conforms to ANSI/UL 73; Certified to CAN/CSA Std. 22.2 No 68-09 (for G3 Max series)
Follower plate for efficient grease dispensing and reduced air pockets
Low-level sensor for monitoring grease supply
Controller for automated operation
CPC (Centralized Pressure Control) for system integration
Vent valve for safe operation
Remote manual run capability for flexible control
Auto-fill shutoff and low-level monitor (on some models)
Illuminated remote run button kit available as accessory
Applications: Industrial, mining, construction, agriculture, transportation, and other sectors requiring reliable automatic lubrication of machinery and equipment
Installation Notes:
Using genuine GRACO parts ensures optimal performance, safety, and compatibility with existing systems.
Ensure reservoir is not overfilled and is properly attached before operation
Use only compatible NLGI #000 to #2 greases or oils with at least 40cSt viscosity
Connect fill hose to inlet fitting for filling; for higher viscosity fluids, start pump to rotate stirring paddle during fill to prevent air pockets
For models with external controller, start pump operation per controller specifications
For Max and Pro models, use the manual run button for manual operation
Install a pressure relief valve at each pump outlet for safety
Monitor system while filling reservoir to prevent overfilling
Regularly check grease level and refill as needed
Inspect for leaks and ensure all fittings are secure
Follow pressure relief procedure before servicing
Use only compatible greases when changing fluids
Consult manual for detailed maintenance schedules and procedures