Fireguard FGT 52 4HR With Pump Bay (40FT/HC) Double Wall Tank - Unity Fuel Solutions

Fireguard FGT 52 4HR With Pump Bay (40FT/HC) Double Wall Tank - Unity Fuel Solutions

SKU: FGT52/4

In stock

Shipping calculated at checkout.
Skip to product information
1 of 1

Collaborating with the Best in the Industry

Fireguard FGT 52 4HR With Pump Bay (40FT/HC) Double Wall Tank - Unity Fuel Solutions

Fireguard FGT 52 4HR With Pump Bay (40FT/HC) Double Wall Tank - Unity Fuel Solutions

SKU: FGT52/4

Shipping calculated at checkout.
atc icon
For precise shipping dates, please contact us.

The Fireguard FGT 52 4HR With Pump Bay (40FT/HC) Double Wall Tank by Unity Fuel Solutions is a high-capacity, aboveground bulk fuel storage and dispensing system, engineered for best-in-class safety, contaminant-free operation, and regulatory compliance in airport, industrial, and fueling infrastructure environments. Combining massive storage with a four-hour fire rating and a secure integrated pump bay, it offers mission-critical performance for sites demanding reliability in high-volume fuel management.

Features and Benefits:

  • 52,000-gallon (approx. 196,841-liter) capacity in a space-efficient 40-foot high-cube (HC) rectangular layout—serves major fueling depots or infrastructure projects.
  • Double-wall mild steel construction with proprietary lightweight 3-inch fireproof insulation for a certified 4-hour fire rating (UL-2085 Protected Aboveground Tank)—significantly lighter than concrete-insulated alternatives for ease of transport and installation.
  • Aviation-grade stainless steel inner tank and wetted piping (verify with supplier for specialty applications) ensures fuel purity for all critical fuels, including aviation, diesel, gasoline, and more.
  • Integrated, weather-sealed pump bay for secure, on-site fueling and equipment protection—ideal for large-scale, continuous, or secure dispensing needs.
  • UL-2085 “Insulated Secondary Containment” and UL-142 certified for fire, projectile, and impact resistance, fully compliant with all fire code requirements at international and federal levels.
  • Integral secondary containment, minimum 110% of tank volume: eliminates the need for traditional bunding walls or dikes, simplifying approvals and reducing installation costs.
  • Leak-detectable interstitial space for continuous environmental monitoring and rapid compliance checks.
  • Lightweight insulation reduces costs for shipping, handling, and installation versus heavier alternatives.
  • Designed for both indoor and outdoor placement—high fire rating enables reduced separation distances per code and regulatory guidance.

Compliance and Safety:

  • Certified to UL-2085 and UL-142 standards; built to Steel Tank Institute F-941 and CARB (California Air Resource Board) emissions requirements.
  • Complies with NFPA 30/30A, ULC S655 (Canada), FAA, and all major federal, state, and local fire and environmental codes.
  • Factory-fitted with emergency venting, overfill protection, corrosion prevention, and robust environmental monitoring options.

Suitable For:

  • Airports, FBOs, heliports, and high-capacity fueling infrastructure needing contaminant-free, secure bulk fuel storage with integrated dispensing.
  • Industrial and commercial fueling depots, government, logistics, and remote operations with high-volume and mission-critical fueling.
  • Sites demanding the highest standards of fire safety, code compliance, and operational flexibility for a variety of flammable and combustible liquids.

Specifications:

  • Capacity: 52,000 gallons (confirm exact with supplier for project-specific sizing and potential metric/equivalent).
  • Dimensions: 40FT/HC container footprint (approx. 12,192mm length × 2,438mm width × 2,896mm height—supplier confirmation recommended).
  • Construction: Double-wall mild steel; proprietary lightweight 3-inch fireproof insulation; optional aviation-grade stainless steel inner tank and piping.
  • Fire Protection: Certified 4-hour fire rating (UL-2085 Protected Aboveground Tank).
  • Pump Bay: Integrated, weather-sealed, supports a range of fuel dispensing equipment and security options.
  • Secondary Containment: Integral—minimum 110% of tank capacity; leak-detectable interstitial space.
  • Certifications: UL-2085, UL-142, STI Fireguard, ULC S655 (Canada), CARB, FAA, and all principal international standards.

Choose the Fireguard FGT 52 4HR With Pump Bay (40FT/HC) Double Wall Tank for top-tier, code-compliant fuel storage and dispensing—delivering proven four-hour fire protection, operational reliability, and regulatory peace of mind for high-stakes infrastructure, airports, or any site where safety and uninterrupted fuel supply are essential.

Collaborating with the Best in the Industry

View full details

Unmatched performance & Expert support

Unmatched Durability and Reliability Unmatched Durability and Reliability

Unmatched Durability and Reliability

Engineered for lasting, heavy-duty performance.

Personalized Setup and Installation Support Personalized Setup and Installation Support

Personalized Setup and Installation Support

Expert guidance for correct setup and optimal performance from day one.

Comprehensive Maintenance Services Comprehensive Maintenance Services

Comprehensive Maintenance Services

Preventative maintenance ensures peak performance and longevity of your equipment.

Fast and Reliable Replacement Parts Fast and Reliable Replacement Parts

Fast and Reliable Replacement Parts

Quick shipping of genuine parts to minimize downtime and repair delays.

Expert 1
Expert 2
Meet our experts

Let's talk about what you need!

Our team is excited to help you!

16815 117 Avenue NW, Unit #110, Edmonton, AB T5M 3V6

info@innoflo.com

(780) 944-4819

View on Map

Our team is excited to help you!