Impossible de charger la disponibilité du service de retrait
For precise shipping dates, please contact us.
The GRACO Husky 1050E is an electric double diaphragm pump with a stainless steel center section, seats, and FKM (Viton) balls and diaphragms. It is designed for reliable transfer of fluids containing solids up to 3.2 mm in size, suitable for industrial, mining, and agricultural applications where robust, maintenance-friendly pumping is required.
Key Features:
Electric Double Diaphragm Pump
Husky 1050E, 1" BSPT
Stainless steel center section, seats; FKM (Viton) balls and diaphragms
Maximum free-flow delivery: 158 lpm (42 gpm)
Maximum output pressure: 70 psi (specific to electric model; metal air-operated models can handle up to 125 psi)
Compatible with fluids containing solids up to 3.2 mm (1/8 in); suitable for water, antifreeze, fuel, and similar fluids
ATEX certification available for certain models; standard AC motor models may not be ATEX certified (check specific part number for certification)
Stall under pressure capability (unique to electric models)
Robust stainless steel and FKM construction for durability and chemical resistance
Easy maintenance with accessible internal components
Reliable performance in harsh environments
Smooth, low-pulsation operation
Applications: Industrial fluid transfer, mining, agriculture, vehicle service, and general maintenance applications where reliable, solid-handling pumps are required.
Installation Notes:
Using genuine GRACO parts ensures compatibility, reliability, and optimal performance. Non-genuine parts may compromise safety and pump longevity.
Ensure proper alignment of inlet and outlet connections (1" BSPT for this model)
Check for correct voltage supply (120V for this model)
Inspect diaphragms, balls, and seats before installation for any damage
Follow manufacturer’s torque specifications for all connections
Regularly inspect and maintain diaphragms and seals to prevent leaks and ensure long service life
Periodically check and replace diaphragms, balls, and seats as needed
Lubricate moving parts according to manufacturer guidelines
Store pump in a dry, temperature-controlled environment (operating/storage temperature: 0°C to 40°C)
Avoid exposure to extreme low temperatures to prevent damage to plastic components (not applicable to this all-metal model, but good practice for mixed-material pumps)
Get Account Level Pricing!